A.2 Message Structure

The ASCII character format used requires 11 bits/character:

• 1 start bit

• 7 information bits

• 1 parity bit

• 2 stop bits


Messages on the remote link fall into the categories of commands and responses.

Commands are messages which are transmitted to a satellite modem, while responses are messages returned
by a satellite modem in response to a command.

The general message structure is as follows:

• Start

Character

• Device

Address

• Command/Response

• End of Message Character

A.2.1 Start Character

A single character precedes all messages transmitted on the remote link. This character flags the start of a
message. This character is:

“<”

for commands

“>”

for responses

A.2.2 Device Address

The device address is the address of the one satellite modem which is designated to receive a transmitted
command, or which is responding to a command.

Valid device addresses are 1 to 3 characters long, and in the range of 1 to 255. Address 0 is reserved as a
global address which simultaneously addresses all devices on a given communications link. Devices do not
acknowledge global commands.

Each satellite modem which is connected to a common remote communications link must be assigned its
own unique address. Addresses are software selectable at the modem, and must be in the range of 1 to 255.