SDM-100A Satellite Modem

Installation

Rev. 0

2–7

2.4.3 Faults (J7)

The Fault connector on the modem is used to interface FORM-C contact closures for the
purpose of fault reporting. There are three FORM-C summary fault contacts:

• Modulator

• Demodulator

• Common

equipment


For further discussion on the monitored faults, refer to Chapter 3.

To obtain a system summary fault, connect all FORM-C contacts in parallel.

The fault interface is provided on a 9-pin female D connector. Screw locks are provided
for mechanical security on the mating connector.

Pin #

Name

Function

1

NO

Common Equipment is OK

2 COM
3

NC

Common Equipment is FAULTED

4

NO

Modulator is OK

5 COM
6

NC

Modulator is FAULTED

7

NO

Demodulator is OK

8 COM
9

NC

Demodulator is FAULTED

Note: A connection between the Common (COM) and Normally Open (NO) contacts
indicates no fault.

2.4.4 TX IF Output (CP1)

This is the transmit IF connector. The output impedance is 75

Ω

(50

Ω

optional), and the

output power level is -5 to -30 dBm, in 0.1 dB steps.

For normal operation, the output will be a QPSK modulated result of the DATA I/O
connector, between 50 and 180 MHz.