Comtech EF Data SDM-100A User Manual

Page 173

Advertising
background image

SDM-100A Satellite Modem

Remote Control Operation

Rev. 0

A–21

Current
Sweep
Value

Command:
Response:

<add/CSV_'cr'
>add/CSV_snnnnn'cr''lf']

Where:

x = < or > (data modifier to indicate that the sweep offset
value is less than or greater than the returned value).

s = + or - (sweep offset from center).

nnnnn = 0 to 35000.


Notes:

1. This command returns the current sweep offset value.
2. The 'x' (< or >) parameter is only returned if the level

has exceeded the computational resolution of the
system.

3. "No Data" is returned if the level cannot be calculated.
4. "Sampling" is returned if not enough data is currently

available to calculate the level.

Interface
Analog
Loopback
Jumper
Status

Status:
Response:

<add/ALBJ_'cr'
>add/ALBJ_xxx'cr''lf']

Where: xxx = ON or OFF.

Note: Only valid when ADPCM board is installed.

Bulk Consol
Analog
Status

Command:
Response:

<add/BCAS_'cr'
>add/BCAS_p1,p2,p3, . . . pn'cr''lf']

This command is similar to the 'BCS_' command but,
returns modem analog parameters.

Where 'pn' is the last parameter returned.

Parameter 1 (p1): Receive Signal Level (ref. "RSL_"
command).

p1 = xsnn.n, receive signal level in dBm.

Parameter 2 (p2): Raw BER (ref. "RBER_" command).

p2 = xm.m

-ee

.

Parameter 3 (p3): Corrected BER (ref. "CBER_"
command).

p3 = xm.m

-ee

.

Parameter 4 (p4): E

b

/N

0

(ref. "EBN0_" command).

p4 = xnn.n, E

b

/N

0

in dB.

Parameter 5 (p5): Current Sweep Value (ref. "CSV_"
command).

p5 = snnnnn, sweep offset value in Hz.


Note: Parameters 2 through 5 are dependent on carrier
acquisition, if the decoder is not locked empty data blocks
are returned (,,,,).

Advertising