A.3.4 system, A.3.5 aupc – Comtech EF Data SDM-100A User Manual

Page 164

Advertising
background image

Remote Control Operation

SDM-100A Satellite Modem

A–12

Rev. 0

A.3.4 System

Time Of
Day

Command:
Response:

Status:
Response:

<add/TIME_hh:mmxx'cr'
>add/TIME_hh:mmxx'cr''lf']

<add/TIME_'cr'
>add/TIME_hh:mmxx'cr''lf']

Where:

hh = 1 to 12 (hours).
mm = 00 to 59 (minutes).
xx = AM or PM.

Date

Command:
Response:

Status:
Response:

<add/DATE_mm/dd/yy'cr'
>add/DATE_mm/dd/yy'cr''lf']

<add/DATE_'cr'
>add/DATE_mm/dd/yy'cr''lf']

Where:

mm = 1 to 12 (month).
dd = 1 to 31 (day).
yy = 00 to 99 (year).

Remote Command:

Response:

<add/REM_'cr'
>add/REM_'cr''lf']

This command configures the modem for remote operation.
The SDM100A will respond to any status request at any time.
However, the SDM100A must be in 'Remote Mode' to change
configuration parameters.

Clear
Stored
Faults

Command:
Response:

<add/CLSF_'cr'
>add/CLSF_'cr''lf']

This command is used to clear all stored faults logged by the
SDM100A.

Modem
Operation
Mode

Command:
Response:

Status:
Response:

<add/MOM_xxxxxxx'cr'
>add/MOM_xxxxxxx'cr''lf']

<add/MOM_'cr'
>add/MOM_xxxxxxx'cr''lf']

Where: xxxxxxx = TX_ONLY, RX_ONLY, or DUPLEX.

This command configures the modem for simplex or duplex
operation modes. When transmit only mode is selected receive
faults are inhibited and when receive only mode is selected
transmit faults are inhibited.

RTS TX-IF
Control
Mode

Command:
Response:

Status:
Response:

<add/RTSM_xxx'cr'
>add/RTSM_xxx'cr''lf']

<add/RTSM_'cr'
>add/RTSM_xxx'cr''lf']

Where: xxx = ON or OFF.

This command configures the modem for the RTS TX-IF
control mode. If "ON" is selected, the TX-IF output will only be
turned on if the incoming RTS signal is asserted (also the TX-
IF output has to be programmed ON and no major modulator
faults are present). If "OFF" is selected, the TX-IF output will
operate normal ignoring the RTS signal.

A.3.5 AUPC

AUPC Local
Enable

Command:
Response:

Status:
Response:

<add/LPC_xxx'cr'
>add/LPC_xxx'cr''lf']

<add/LPC_'cr'
>add/LPC_xxx'cr''lf']

Where: xxx = ON or OFF.

Note: When programmed ON, the MOP (Modulator Output
Power) command is not allowed, only MOP status is allowed.

AUPC
Nominal
Power Level

Command:
Response:

Status:
Response:

<add/NOMP_snn.n'cr'
>add/NOMP_snn.n'cr''lf']

<add/NOMP_'cr'
>add/NOMP_snn.n'cr''lf']

Where: snn.n = -30.0 to -5.0, in 0.1 steps (nominal range in
dBm).

Note: The nominal power range is modified relative to the value
specified by the modulator power offset (MPO_).

AUPC
Maximum
Power Limit

Command:
Response:

Status:
Response:

<add/MAXP_snn.n'cr'
>add/MAXP_snn.n'cr''lf']

<add/MAXP_'cr'
>add/MAXP_snn.n'cr''lf']

Where: snn.n = -30.0 to -5.0, in 0.1 steps (nominal range in
dBm).

Note: The nominal power range is modified relative to the value
specified by the modulator power offset (MPO_).

Advertising