Comtech EF Data SDM-100A User Manual

Page 178

Advertising
background image

Remote Control Operation

SDM-100A Satellite Modem

A–26

Rev. 0

Change
Status

Command:
Response:

<add/CS_'cr'
>add/CS_x'cr''lf']

Where: The 'x' character is defined as follows:

'@' = no change since last BCS_ and BCSF_ polls.

'A' = BCS_ response has changed since last BCS_ poll.

'B' = BCSF_ response has changed since last BCSF_
poll.

'C' = Both responses have changed since last BCS_
and BCSF_ polls.


This command indicates that a change has or has not
occurred on either the BCS_ or the BCSF_ response since
the last BCS_ or BCSF_ poll.

Equipment
Type

Command:
Response:

<add/ET_'cr'
>add/ET_tttttttt_xxx.yyy.zzz'cr''lf']

Where:

tttttttt = Equipment type.
xxx.yyy.zzz = Software version.


This command returns the equipment type and the
software version of the addressed device.

Monitor &
Control
Firmware
Information

Command:
Response:

<add/MCFI_'cr'
>add/MCFI_'cr'
VER_xxx.yyy.zzz'cr'
FW/nnnnnn-ddr'cr'
mm/dd/yy'cr''lf']

Where:

xxx.yyy.zzz = Software version number (0.0.0 to
999.999.999).

nnnnnn = Firmware number (0 to 999999).

dd = Firmware dash number (0 to 99).

r = Firmware revision (-, or A to Z).

DATA ROM
Firmware
Information

Command:
Response:

<add/DFI_'cr'
>add/DFI_'cr'
DSP_FW/nnnnnn-ddr'cr'
DSP_mm/dd/yy'cr'
FPGA_FW/nnnnnn-ddr'cr'
FPGA_mm/dd/yy'cr''lf']

Where:

nnnnnn = Firmware number (0 to 999999).
dd = Firmware dash number (0 to 99).
r = Firmware revision (-, or A to Z).

Interface
Type

Command:
Response:

<add/IT_'cr'
>add/IT_ttttt'cr''lf']

Where: ttttt = RS422, V.35, RS232, ADPCM, or ASYNC.

This command returns the Interface equipment type.

Bulk Consol
Status
AUPC

Command:
Response:

<add/BCSA_'cr'
>add/BCSA_p1,p2,p3, . . . pn'cr''lf']

Where 'pn' is the last parameter returned.

Parameter 1 (p1): Local AUPC enable ON/OFF.

p1 = n, where 'n' is '0' (off) or '1' (on).

Parameter 2 (p2): Nominal Power Value.

p2 = snn.n, where 'snn.n' Nominal Power Value in dBm.

Parameter 3 (p3): Minimum Power Value.

p3 = snn.n, where 'snn.n' Minimum Power Value in
dBm.

Parameter 4 (p4): Maximum Power Value.

p4 = snn.n, where 'snn.n' Maximum Power Value in
dBm.

Parameter 5 (p5): E

b

/N

0

Target Set Point.

p5 = n.n, where 'n.n' E

b

/N

0

Target Set Point in dB.

Parameter 6 (p6): Max. Tracking Rate.

p6 = n.n, where 'n.n' is the Max. Tracking Rate in
dB/Min.

Parameter 7 (p7): Local Carrier Loss.

p7 = n, where 'n' is '0' (HOLD), '1' (NOMINAL), or '2'
(MAXIMUM).

Parameter 8 (p8): Remote Carrier Loss.

p8 = n, where 'n' is '0' (HOLD), '1' (NOMINAL), or '2'
(MAXIMUM).

Advertising