1 modulator faults: type 1 operation, 2 demodulator faults: type 1 operation, 3 common equipment faults: type 1 operation – Comtech EF Data SDM-100A User Manual

Page 97

Advertising
background image

SDM-100A Satellite Modem

Operation

Rev. 0

3–63

3.2.2.3.1 Modulator Faults: Type 1 Operation

Fault

Description

IF Synthesizer

Modulator IF synthesizer fault.

Data Clock Act

Activity detector alarm of the selected interface receive clock. The
interface will fall back to the satellite clock when this fault is active.

Data Clock Syn

Transmit clock synthesizer fault. Indicates the internal VCO has not
locked to the incoming data clock.

I Channel

I channel data activity fault.

Q Channel

Q channel data activity fault.

AGC Level

TX-IF AGC level fault.

Module

Modulator module fault. Typically indicates the modulator module is
missing or will not program.

3.2.2.3.2 Demodulator Faults: Type 1 Operation

Fault

Description

Carrier Detect

Carrier detect fault. Indicates the decoder is not locked.

IF Synthesizer

Demodulator IF synthesizer fault. Indicates that the IF synthesizer is not
locked.

Data Clock Syn

Receive clock synthesizer fault. Indicates the internal VCO has not
locked to the incoming data clock.

I Channel

I channel activity fault. Indicates a loss of activity in the I channel of the
quadrature demodulator.

Q Channel

Q channel activity fault. Indicates a loss of activity in the Q channel of the
quadrature demodulator.

Descrambler

Descrambler activity alarm. Indicates a loss of activity in the
descrambler.

BER Threshold

Secondary alarm result of the BER threshold set in the Demod
Configuration menu.

Module Demodulator/decoder module fault. Typically indicates that the

Demod/decoder module is missing or will not program.

3.2.2.3.3 Common Equipment Faults: Type 1 Operation

Fault

Description

Battery/Clock

Battery or clock fault.

-12V Supply

-12V power supply fault.

+12V Supply

+12V power supply fault.

+5V Supply

+5V power supply fault.

Controller

Controller fault. Typically indicates the controller has gone through a
power on-off cycle.

Interface Module

Interface module fault. Typically indicates that the interface module is
missing or will not program.

Advertising