Figure 3-18. configuration (type 1 operation) – Comtech EF Data SDM-100A User Manual

Page 88

Advertising
background image

Operation

SDM-100A Satellite Modem

3–54

Rev.

0

SDM-100A "TYPE"

VER: 14.7.4

FUNCTION SELECT

CONFIGURATION

TX-X CODE_RATE/

TYPE

RX-X CODE_RATE/

TYPE

TX-IF FREQUENCY

RX-IF FREQUENCY

TX-IF OUTPUT

TX POWER LEVEL

X = A, B, C, D, OR V

TX-A QPSK 1/2 [64.000 kbit/s]
TX-B QPSK 1/2 [96.000 kbit/s]
TX-C QPSK 1/2 [128.00 kbit/s]
TX-D QPSK 1/2 [32.00 kbit/s]
TX-V QPSK 1/2 [19.2 kbit/s]

X = A, B, C, D, OR V

RX-A QPSK 1/2 [64.000 kbit/s]
RX-B QPSK 1/2 [96.000 kbit/s]
RX-C QPSK 1/2 [128.00 kbit/s]
RX-D QPSK 1/2 [32.00 kbit/s]
RX-V QPSK 1/2 [19.2 kbit/s]

50 to 180 MHz

in 2.5 kHz steps

50 to 180 MHz

in 2.5 kHz steps

ON

OFF

-5 to -30 dBm

in 0.1 dBm steps

RF LOOP BACK

ON

OFF

IF LOOP BACK

ON

OFF

B-BAND LOOP BACK

ON

OFF

V.35 SCRAMBLER

ON

OFF

V.35 DESCRAMBLER

ON

OFF

ACCESS TO

SUBMENU

CONDITIONAL OR

OPTION-DEPENDENT

Parameter Information

Key:

DIFF. ENCODER

ON

OFF

TX CLOCK

SOURCE

SCT (INTERNAL)

TX TERR (EXT)

RX CLOCK

PHASE

NORMAL

INVERT

REACQUISITION

0 to 999 seconds

CARRIER MODE

NORMAL (OFF)

CENTER

OFFSET

DUAL

Figure 3-18. Configuration (Type 1 Operation)

Advertising