Comtech EF Data SDM-100A User Manual
Page 161
![background image](/files/778892/content/doc161.png)
SDM-100A Satellite Modem
Remote Control Operation
Rev. 0
A–9
Interface
Subscriber/
Trunk
Emulation
Command:
Response:
Status:
Response:
<add/SBTR_xxx'cr'
>add/SBTR_xxx'cr''lf']
<add/SBTR_'cr'
>add/SBTR_xxx'cr''lf']
Where: xxx = SUB or TRK.
Note: Only valid when ADPCM board is installed.
E & M
Signal Type
Command:
Response:
Status:
Response:
<add/EMS_n'cr'
>add/EMS_n'cr''lf']
<add/EMS_'cr'
>add/EMS_n'cr''lf']
Where: n = 1 to 5, in steps of 1.
Note: Only valid when ADPCM board is installed.
Interface
Encoding
Law
Command:
Response:
Status:
Response:
<add/LAW_y'cr'
>add/LAW_y'cr''lf']
<add/LAW_'cr
>add/LAW_y'cr''lf']
Where: y = A (A-Law) or U (u-Law).
Off Hook
Alert Enable
Command:
Response:
Status:
Response:
<add/HOOK_xxx'cr'
>add/HOOK_xxx'cr''lf']
<add/HOOK_'cr
>add/HOOK_xxx'cr''lf']
Where: xxx = ON or OFF.
Note: Only valid when ADPCM board is installed.
Interface
Service
Channel
Level
Command:
Response:
Status:
Response:
<add/ISCL_xx_nnn'cr'
>add/ISCL_xx_nnn'cr''lf']
<add/ISCL_xx'cr'
>add/ISCL_xx_nnn'cr''lf']
Where:
xx = TX or RX (service channel designator).
nnn = -20 to +10, in steps of 1 (service channel level in
dBm).
Note: Only valid when ADPCM board is installed.
Interface
RD Signal
Command:
Response:
Status:
Response:
<add/RD_xxx'cr'
>add/RD_xxx'cr''lf']
<add/RD_'cr'
>add/RD_xxx'cr''lf']
Where: xxx = NRM or INV.
Note: Only valid when ADPCM board is installed.
Interface
SD Signal
Command:
Response:
Status:
Response:
<add/SD_xxx'cr'
>add/SD_xxx'cr''lf']
<add/SD_'cr'
>add/SD_xxx'cr''lf']
Where: xxx = NRM or INV.
Note: Only valid when ADPCM board is installed.
Interface
RR Signal
Command:
Response:
Status:
Response:
<add/RR_xxx'cr'
>add/RR_xxx'cr''lf']
<add/RR_'cr'
>add/RR_xxx'cr''lf']
Where: xxx = NRM or INV.
Note: Only valid when ADPCM board is installed.
Interface
DM Signal
Command:
Response:
Status:
Response:
<add/DM_xxx'cr'
>add/DM_xxx'cr''lf']
<add/DM_'cr'
>add/DM_xxx'cr''lf']
Where: xxx = NRM or INV.
Note: Only valid when ADPCM board is installed.
Interface
ASYNC
Communi-
cations
Program
Command:
Response:
Status:
Response:
<add/ACP_xxx'cr'
>add/ACP_xxx'cr''lf']
<add/ACP_'cr'
>add/ACP_xxx'cr''lf']
Where: xxx = ON or OFF.
Note: Only valid when ASYNC board is installed.
ASYNC
Transmit
Overhead
Baud Rate
Command:
Response:
Status:
Response:
<add/TOBR_nnnnn'cr'
>add/TOBR_nnnnn'cr''lf']
<add/TOBR_'cr'
>add/TOBR_nnnnn'cr''lf']
Where: nnnnn = 150, 300, 600, 1200, or 2400.
Note: Only valid when ASYNC board is installed with ASYNC
enabled.