If a sequence is recalled by pressing the Store key, the following display is shown:


The individual fields have the following function:

NAME :

names the sequence.

SINGLE inverted:

the sequence runs once and stops

after the last step.

SINGLE not inverted: the sequence runs endlessly.
LINK F inverted:

specifiies the fade time in %.

LINK F nicht invertiert: specifiies the fade time in absolute
values.
FADETIME:

enters fade time with the left encoder

wheel

(FADETIME).

STEP:

selects the desired step with the

middle encoder wheel.

NEXTTIME invertiert: enters step length with the right encoder wheel (NEXTTIME),

inserts intermediate steps with the softkey ID.

TRIGP:

enters the trigpoint. When the function is activated (displayed inverted), enter the
data with the right encoder wheel (TRIGPOINT).

ID:

numbers intermediate steps. When the function is activated, enter the data with
the right encoder wheel (ID).

GO-TO

selections steps directly, when GO-TO key is used in combination with the keys
of the CUES/CHASES/SEQUENCE section.


If you press the softkey MODIFY in addition, the following functions are shown on the display:


DUP ST:

duplicaties the active step.

DEL ST:

deletes the active step.

CLEAR:

deletes the complete sequence

(attention:

no

confirmation

prompt).

BLOCK:

forms a block from a several

successive steps.

LINK:

links a chase within a sequence.

RENUM:

renumbers the sequence steps using

integral

numbers.




The following data are related to the example and will vary from sequence to sequence:

L: 2:

The sequence has a length of two steps.

A 05:

The activated sequence is stored on Bank A key 05.

OFF:

The sequence selected is deactivated.


With the following functions, you can determine flow control of a sequence. The functions are activated
with the corresponding keys in the Sequence Control section:

AUTO:

The steps run automatically according to preprogrammed time intervals. The
auto-function is activated by pressing the Rate key in the Sequence Control
section.

MFAD:

The step is faded with the ManFader fader.

GO:

The step is switched with the Go+ and Go- keys.

SOUND:

The step is switched with the Sound function.




Advertising