3.1.9 Setting the Point Table

3 -28

Figure 3.53 Point Table Menu Screen

J

Point Table Save/Reset

Operating procedures from the Point Table Save/Reset Screen are described below.

A

X

I

S

Figure 3.54 Point Table Save/Reset Screen

Saving Point Tables

1. Input the table number in the input area to the right of TABLE NO = and press the ENT

Key to confirm.

2. Input the leading # register number in the input area to the right of START = and press the

ENT Key to confirm.

3. Input the number of points in the table in the input area to the right of NUMBER = and

press the ENT Key.

4. Input the number of axes in the input area to the right of AXIS = and press the ENT Key

to confirm. The last # register will automatically be displayed in the space to the right of
STOP =.

5. To switch to Physical Axis Setting Screen, press the DISP CHG + Left or Right Cursor

Keys. (Refer to the following screen.)

6. Select the axis to be set using Up and Down Cursor Keys.

The cursor will be to the right of the axis number to be set.

7. Input the physical axis number in the above space using the Numeric Keys, and press the

ENT Key to confirm.

The physical axis number will be set to the right space of the axis number.