5 Trial Operation (Checking Servomotor Operation)

5-6

6

Press the Up Cursor Key to rotate the ser-

vomotor in the forward direction and press

the Down Cursor Key to rotate it in

reverse. The servomotor will operate

while the key is being pressed. (The fac-
tory setting is 500 min

-1

.)

Confirm that the servomotor operation is

correct. At the same time, carefully

inspect the servomotor’s condition and

check the following points in particular.

If a problem is found, correct it.

• Is there any unusual vibration?

• Is there any unusual sound?

• Is the temperature rising unusually

high?

7

Press the MODE/SET Key. The servo-

motor power will be OFF.

Note:

The servomotor can be turned OFF by

pressing the DATA/SHIFT Key for

approximately one second.

8

Press the DATA/SHIFT Key for approxi-

mately one second.

"Fn002" is displayed again.

9

Press the MODE/SET Key to return to

the initial display (step 1).

(cont’d)

Step

Display after operation

Keys

Operation

MODE/SET

DATA/

Forward
rotation

Reverse
rotation

/

/

MODE/SET

DATA/

/

/

MODE/SET

DATA/

Alternate

display

MODE/SET

DATA/

Advertising