2 system configuration diagram 3-5 – Yaskawa Sigma-5 User Manual: Setup for Rotary Motors User Manual

Page 63

Advertising
background image

3.2 System Configuration Diagram

3-5

3

Wiring and Connection

• Using a Single-phase, 200-V Power Supply

The

Σ-V Series SERVOPACK for a 200-V power supply input has input specifica-

tions for a three-phase power supply, but some models can also be used with a single-
phase 200-V power supply. For details, refer to

Σ

-V Series User's Manual Design and

Maintenance Rotational Motor/Analog Voltage and Pulse Train Reference (SIEP

S800000 45).

∗1. Use a 24 VDC power supply. (not included)

∗2. Before connecting an external regenerative resistor to the SERVOPACK, refer to 3.4 Con-

necting Regenerative Resistors.

200 VAC

SGMJV/SGMAV/SGMPS/

SGMGV/SGMSV

Servomotor

SGDV-

A01

SERVOPACK

Power supply
Single-phase 200 VAC

Noise filter

Molded-case

circuit breaker

(MCCB)

Protects the power supply

line by shutting the

circuit OFF when

overcurrent is

detected.

Used to eliminate

external noise from

the power line.

Magnetic

contactor

Turns the servo

ON and OFF.

Install a surge

absorber.

Brake power supply*

1

Regenerative

resistor*

2

Used for a servomotor

with a brake.

Turns the brake power supply

ON and OFF.

Install a surge absorber.

Encoder cable

When not using the safety

function, use the SERVOPACK

with the safety function jumper

connector (JZSP-CVH05-E,

provided as an accessory)

inserted.

When using the safety function,

insert a connection cable

specifically for the safety function.

Safety function

devices

I/O signal cable

Connection cable

for digital operator

Connection cable

for personal computer

Digital

operator

Personal

computer

Host controller

Battery case

(when an absolute

encoder is used.)

Magnetic contactor

R

T

Motor main

circuit cable

Advertising