3 Wiring and Connection

3.3.3 Typical Main Circuit Wiring Examples

3-26

„

Three-phase 400 V, SGDV-†††D

• SGDV-1R9D, 3R5D, 5R4D, 8R4D, 120D, 170D

• SGDV-210D, 260D, 280D, 370D

1QF: Molded-case circuit breaker
1FIL: Noise filter
1KM: Magnetic contactor (for control power supply)
2KM: Magnetic contactor (for main power supply)
1Ry: Relay

1PL: Indicator lamp
1SA: Surge absorber
2SA: Surge absorber
3SA: Surge absorber
1D: Flywheel diode

ENC

SGDV-

D

U

V

W

M

0 V

1Ry

ALM+

ALM−

31

32

1D

CN1

1QF

R S T

1FIL

+24 V

3SA

B2
B3

1

2

B1/

1Ry

1PL

1KM

2KM

1SA

1Ry

1KM

2SA

L1

2KM

L2
L3

24 V

DC power

supply

24 V

+

1KM

0 V

1KM

(For servo

alarm display)

supply ON

Servo power

supply OFF

Servo power

SERVOPACK

ENC

SGDV-

D

U

V

W

M

0 V

1Ry

ALM+

ALM−

31

32

1D

CN1

1QF

R S T

1FIL

+24 V

3SA

B2

1

2

B1/

1Ry

1PL

1KM

2KM

1SA

1Ry

1KM

2SA

L1

2KM

L2
L3

24 V

DC power

supply

(24 V)

+

1KM

0 V

1KM

Regenerative
resistor unit

(For servo

alarm display)

supply ON

Servo power

supply OFF

Servo power

SERVOPACK

1QF: Molded-case circuit breaker
1FIL: Noise filter
1KM: Magnetic contactor (for control power supply)
2KM: Magnetic contactor (for main power supply)
1Ry: Relay

1PL: Indicator lamp
1SA: Surge absorber
2SA: Surge absorber
3SA: Surge absorber
1D: Flywheel diode

Advertising