2.4 EMC Installation Conditions

2-23

2

Installation

„

Three-phase 200 V

• SGDV-†††A11A (††† = R70, R90, 1R6, 2R8, 3R8, 5R5, 7R6)

Symbol

Cable Name

Specification

c

I/O signal cable

Shield cable

d

Safety signal cable

Shield cable

e

Motor main circuit cable

Shield cable

f

Encoder cable

Shield cable

g

Main circuit cable

Shield cable

h

MECHATROLINK-II communication cable

Shield cable

Shield box

Clamp

Clamp

Clamp

One turn

Core

Core

Two turn

Two turn

Clamp

MECHATROLINK-II

controller

Clamp

Power supply:

Three-phase

200 VAC

SERVOPACK

Encoder

Servomotor

Brake

Clamp

Noise

filter

Brake Power

Supply

Surge

absorber

Core

Core

Core

Core

Safety unit

U, V, W

L1, L2, L3

L1C, L2C

CN2

CN1

CN6A, CN6B

PE

PE

2

1

3

4

5

6

CN8

One turn

Host

controller