Yaskawa Sigma-5 User Manual: Setup for Rotary Motors User Manual

Page 87

Advertising
background image

3.3 Main Circuit Wiring

3-29

3

Wiring and Connection

„

Wiring Procedure

1.

Remove the main circuit terminal connector from the SERVOPACK.

2.

Strip the end of the wires.

3.

Open the wire terminal on the terminal connector housing with a tool,
using the following methods. Either method can be used to open the
wire terminal.

„

Using a spring opener

Use the spring opener provided with the SERVOPACK to open the wire terminal as
shown in the diagram.

Note: The spring opener (1981045-1) made by Tyco Electronics AMP K.K. can also be used.

Main circuit
terminal connector

Enlarged View

Lock

1㧚Press

the lock.

2. Remove the main

circuit terminal

connector while

pressing the lock.

Applicable wire sizes:

8 to 9 mm

Refer to 3.3.2 SERVOPACK
Main Circuit Wire Size
.

Wire

Spring opener