2 sgdv-****11* (m-ii model), 2 sgdv-11 (m-ii model), Single-phase 100 v – Yaskawa Sigma-5 User Manual: Setup for Rotary Motors User Manual
Page 42: 2installation
Advertising

2.4 EMC Installation Conditions
2-21
2
Installation
2.4.2 SGDV-11 (M-II Model)
Single-phase 100 V
• SGDV-F11A ( = R70, R90, 2R1, 2R8)
Symbol
Cable Name
Specification
c
I/O signal cable
Shield cable
d
Safety signal cable
Shield cable
e
Motor main circuit cable
Shield cable
f
Encoder cable
Shield cable
g
Main circuit cable
Shield cable
h
MECHATROLINK-II communication cable Shield cable
U, V, W
L1, L2
L1C, L2C
CN2
CN1
Shield box
PE
PE
1
3
4
5
Clamp
Clamp
Clamp
CN8
2
One turn
Core
Core
Two turn
Two turn
Clamp
MECHATROLINK-II
controller
CN6A,CN6B
6
Clamp
Power supply:
Single-phase
100 VAC
SERVOPACK
Encoder
Servomotor
Brake
Clamp
Noise
filter
Brake Power
Supply
Surge
absorber
Two turn
Core
Core
Core
Core
Safety unit
One turn
Host
controller
Advertising