2.4 EMC Installation Conditions

2-21

2

Installation

2.4.2 SGDV-††††11† (M-II Model)

„

Single-phase 100 V

• SGDV-†††F11A (††† = R70, R90, 2R1, 2R8)

Symbol

Cable Name

Specification

c

I/O signal cable

Shield cable

d

Safety signal cable

Shield cable

e

Motor main circuit cable

Shield cable

f

Encoder cable

Shield cable

g

Main circuit cable

Shield cable

h

MECHATROLINK-II communication cable Shield cable

U, V, W

L1, L2

L1C, L2C

CN2

CN1

Shield box

PE

PE

1

3

4

5

Clamp

Clamp

Clamp

CN8

2

One turn

Core

Core

Two turn

Two turn

Clamp

MECHATROLINK-II

controller

CN6A,CN6B

6

Clamp

Power supply:

Single-phase

100 VAC

SERVOPACK

Encoder

Servomotor

Brake

Clamp

Noise

filter

Brake Power

Supply

Surge

absorber

Two turn

Core

Core

Core

Core

Safety unit

One turn

Host

controller