5 connecting a safety function device – Yaskawa Sigma-5 User Manual: Setup for Rotary Motors User Manual
Page 96
 
4.5 Connecting a Safety Function Device
4-5
4
Safety Function
4.5
Connecting a Safety Function Device
There are the following two types of safety function’s jumper connectors that are pro-
vided with the SERVOPACKs. The safety function’s jumper connector must be 
removed to attach a safety function device. Read the following procedure carefully 
and then attach the safety function device.
Connect a safety function device using the following procedure.
1.
Remove the servomotor connection terminal connector while pressing 
the lock.
Applicable SERVOPACKs: 
SGDV-R70F, -R90F, -2R1F, -R70A, -R90A, -1R6A, -2R8A, -1R9D, -3R5D, -
5R4D
For SERVOPACK models not listed above, it is not necessary to remove the 
servomotor connection terminal connector. Go to step 2. 
Previous model
New model
Servomotor
connection
terminal connector
Enlarged View
Lock
1㧚Press the lock.
2㧚Remove the servomotor
 connection terminal connector
 while pressing the lock.