3.3 Main Circuit Wiring

3-27

3

Wiring and Connection

„

Precautions When Using More Than One SERVOPACK

This section shows an example of the wiring when more than one SERVOPACK is
used and the precautions.

• Wiring Example (Analog pulse model)

Connect the alarm output (ALM) terminals for the three SERVOPACKs in series to
enable alarm detection relay 1RY to operate.

When the alarm occurs, the ALM output signal transistor is turned OFF.

L1

L2
L3

L1C

L2C

SERVOPACK

Servomotor

Servomotor

M

Servomotor

M

M

Relay

terminal

Relay

terminal

Relay

terminal

1QF:
1FIL:
1KM: Magnetic contactor
(for control power supply)
2KM:
(for main power supply)
1Ry:
1PL:
1SA:
2SA:
3SA:
1D:

Molded-case circuit breaker
Noise filter

Relay

Magnetic contactor

Indicator lamp
Surge absorber

1Ry

+24 V

CN1

CN1

CN1

31

ALM+

32

ALM

-

0 V

L1

L2
L3

31

ALM+

32

ALM

-

L1

L2

L3

L1C

ID

31

ALM+

32

ALM

-

L2C

L1C

L2C

SERVOPACK

SERVOPACK

Surge absorber
Surge absorber
Flywheel diode

supply ON

1KM

R S

T

1QF

2KM

Power supply

1FIL

Relay
terminal

3SA

1KM

(For servo alarm

display)

1Ry

1PL

1KM

2KM

1SA

Servo power

supply OFF

Servo power

1Ry

1KM

2SA

Advertising