Three-phase 400 v – Yaskawa Sigma-5 User Manual: Setup for Rotary Motors User Manual

Page 49

Advertising
background image

2 Installation

2.4.2 SGDV-††††11† (M-II Model)

2-28

„

Three-phase 400 V

• SGDV-†††D11A (††† = 210, 260, 280, 370)

∗1. Products that have received CE marking are recommended for the 24 VDC power supply.

∗2. Install the following noise filter on the power line between the single-phase 200 V power

supply and the 24 VDC power supply.
Model number: FN2070-6/07 (SCHAFFNER)

∗3. For more information on this filter, refer to

Σ

-V Series Product Catalog. (KAEP S800000

42)

Symbol

Cable Name

Specification

c

I/O signal cable

Shield cable

d

Safety signal cable

Shield cable

e

Motor main circuit cable

Shield cable

f

Encoder cable

Shield cable

g

Control power cable

Shield cable

h

Main circuit cable

Shield cable

i

Regenerative resistor unit cable

Non-shield cable

j

MECHATROLINK-II communication cable Shield cable

U, V, W

L1, L2, L3

24 V, 0 V

CN2

CN1

Encoder

PE

PE

Servomotor

Brake

1

2

3

6

5

CN8

Clamp

Clamp

MECHATROLINK-II

controller

CN6A, CN6B

8

Clamp

B1, B2

7

4

SERVOPACK

Brake Power

Supply

Safety unit

Power supply:

Single-phase

200 VAC

Power supply:

Three-phase

400 VAC

Shield box

Clamp

Clamp

Clamp

Clamp

Noise

filter*

3

Surge

absorber

Surge

absorber

Noise

filter*

2

Control

power

supply

24 VDC*

1

Clamp

Regenerative

resistor cable

Host

controller

Advertising