2 system configuration diagram 3-13 – Yaskawa Sigma-5 User Manual: Setup for Rotary Motors User Manual

Page 71

Advertising
background image

3.2 System Configuration Diagram

3-13

3

Wiring and Connection

• Using a Single-phase, 200-V Power Supply

The

Σ-V Series SERVOPACK for a 200-V power supply input has input specifica-

tions for a three-phase power supply, but some models can also be used with a single-
phase 200-V power supply. For details, refer to

Σ

-V Series User's Manual Design and

Maintenance Rotational Motor/MECHATROLINK-III Communications Reference

(manual no.: SIEP S800000 64).

∗1. Use a 24 VDC power supply (not included.).

∗2. Before connecting an external regenerative resistor to the SERVOPACK, refer to 3.4 Con-

necting Regenerative Resistors.

Motor main

circuit cable

Encoder cable

Battery case

Brake power supply

∗1

Magnetic contactor

∗2

Noise filter

Molded-case

circuit breaker

(MCCB)

Magnetic contactor

I/O signal cable

SGDV-

A21

SERVOPACK

SGMJV/SGMAV/SGMPS/
SGMGV/SGMSV
Servomotor

Power supply
Single-phase 200 VAC

Protcts the power supply

line by shutting the

circuit OFF when

overcurrent is detected.

Used to eliminate

external noise from

the power line.

Used for a servomotor
with a brake.

Turns the servo

ON and OFF.

Install a surge

absorber.

Turns the brake power supply

ON and OFF.

Install a surge absorber.

(when an absolute

encoder is used.)

Personal
computer

Connection cable
for personal computer

Digital
operator

When not using the safety
function, use the SERVOPACK
with the safety function jumper
connector (JZSP-CVH05-E,
provided as an accessory)
inserted.

When using the safety function,
insert a connection cable
specifically for the safety function.

Safety function
devices

Connection cable
for digital operator

200 VAC

Host controller

Regenerative

resistor

Connect to the
MECHATROLINK-III.

R

T

Advertising