background image

3.4 Connecting Regenerative Resistors

3-31

3

Wiring and Connection

3.4

Connecting Regenerative Resistors

This section describes how to connect regenerative resistors and set the regenerative
resistor capacity. To learn how to select a regenerative resistor, and for detailed spec-
ifications, refer to

Σ

-V Series Product Catalog (KAEP S800000 42).

For more information on how to set the capacity of regenerative resistors, refer to

Σ

-V Series User’s Manual Design and Maintenance (SIEP S800000 45/46/60/64).

3.4.1 Connecting Regenerative Resistor

„

SERVOPACKs: Model SGDV-R70F, R90F, 2R1F, 2R8F, R70A, R90A,
1R6A, 2R8A

Connect an external regenerative resistor between B1/ and B2 terminals. After
connecting a resistor, select the capacity.

WARNING

• Be sure to connect the regenerative resistor correctly.

Failure to observe this warning may result in fire or damage to the product.

Enlarged View