Three-phase 200 v, 2installation – Yaskawa Sigma-5 User Manual: Setup for Rotary Motors User Manual

Page 38

Advertising
background image

2.4 EMC Installation Conditions

2-17

2

Installation

„

Three-phase 200 V

• SGDV-†††A01A (††† = 180, 200, 330)

Symbol

Cable Name

Specification

c

I/O signal cable

Shield cable

d

Safety signal cable

Shield cable

e

Motor main circuit cable

Shield cable

f

Encoder cable

Shield cable

g

Main circuit cable

Shield cable

U, V, W

L1, L2, L3

L1C, L2C

CN2

CN1

PE

PE

1

3

4

5

CN8

2

Power supply:

Three-phase

200 VAC

Shield box

SERVOPACK

Clamp

Noise

filter

Brake Power

Supply

Clamp

Clamp

Clamp

Surge

absorber

Core

Core

Core

Two turn

Two turn

Clamp

Encoder

Servomotor

Brake

Host

controller

Safety unit

One turn

Advertising