3.4 Connecting Regenerative Resistors

3-33

3

Wiring and Connection

„

SERVOPACKs: Model SGDV-470A, 550A, 590A, 780A, 210D, 260D,
280D, 370D

No built-in regenerative resistor is provided, so the external regenerative resistor is
required. The regenerative resistor units are as follow:

Connect a regenerative resistor unit between B1/ and B2 terminals.

When using a regenerative resistor unit, set Pn600 to 0 W (factory setting).

Main

Circuit

Power

Supply

Applicable

SERVOPACK

Model SGDV

Applicable

Regenerative

Resistor Unit

Resistance

(

Ω)

Specifications

Three-
phase
200 V

470A

JUSP-RA04-E

6.25

25

Ω (220 W); 4 resistors in paral-

lel

550A, 590A,
780A

JUSP-RA05-E

3.13

25

Ω (220 W); 8 resistors in paral-

lel

Three-
phase
400 V

210D, 260D

JUSP-RA18-E

18

18

Ω (220 W); 2 resistors in series

with 2 in parallel.

280D, 370D

JUSP-RA19-E

14.25

28.5

Ω (220 W); 2 resistors in

series with 4 in parallel.

Regenerative Resistor Unit