Sgdv-†††de1a – Yaskawa Sigma-5 User Manual: Setup for Rotary Motors User Manual

Page 76

Advertising
background image

3 Wiring and Connection

3.2.4 Connecting to SGDV-††††E1A SERVOPACK (Command Option Attachable Type)

3-18

„

SGDV-†††DE1A

∗1. Use a 24-VDC power supply with double insulation or reinforced insulation. (The power

supply is not included)

∗2. Before connecting an external regenerative resistor to the SERVOPACK, refer to 3.4 Con-

necting Regenerative Resistors.

∗3. Use a following power supply for 90-V brake. For details, refer to

Σ

-V series Product

Catalog (KAEP S800000 42).

• For 200-V input voltage: LPSE-2H01-E
• For 100-V input voltage: LPDE-1H01-E

∗4. For connection to the command option module, refer to the user’s manual of the corre-

sponding option module.

R S T

Noise filter

Molded-case

circuit breaker

(MCCB)

Magnetic

contactor

I/O signal cable

Power supply

Three-phase 400 VAC

Protects the power

supply line by shutting

the circuit OFF when

overcurrent is

detected.

Used to eliminate

external noise from

the power line.

Turns the servo

ON and OFF.

Install a surge

absorber.

Connection cable

for digital operator

Connection cable

for personal computer

Personal

computer

Motor main

circuit cable

Encoder cable

SGMGV/SGMSV

Servomotor

When not using the safety

function, use the SERVOPACK

with the safety function jumper

connector (JZSP-CVH05-E,

provided as an accessory)

inserted.

When using the safety function,

insert a connection cable

specifically for the safety function.

Safety function

devices

SGDV-

DE1A

SERVOPACK

Digital

operator

Brake power

supply*

3

Magnetic contactor

Turns the brake power supply

ON and OFF.

Install a surge absorber.

Used for a servomotor

with a 90 V brake.

Regenerative

resistor *

2

DC power

supply (24 V)

100/200 VAC

*

1

Option module

External LED indicator,

external device, etc.

*

4

Battery case

(when an absolute

encoder is used.)