3.3 Main Circuit Wiring

3-23

3

Wiring and Connection

„

Three-phase, 400 V

External

Terminal Name

Terminal

Symbols

SERVOPACK Model SGDV-

1R9 3R5 5R4 8R4 120 170 210 260 280 370

Main circuit

power input

terminals

L1, L2, L3

HIV1.25

HIV2.0

HIV3.5

HIV

5.5

HIV

8.0

HIV

14.0

Control power

input terminals

24V, 0V

HIV1.25

Servomotor

connection

terminals

U, V, W

HIV1.25

HIV2.0

HIV

3.5

HIV5.5

HIV

8.0

HIV

14.0

External

regenerative

resistor

connection

terminals

B1/

, B2

(B1, B2)

HIV1.25

HIV

2.0

HIV3.5

HIV

5.5

HIV

8.0

Ground terminal

HIV2.0 or higher