3 Wiring and Connection

3.2.1 Connecting to SGDV-††††01† SERVOPACK (Analog Pulse Model)

3-6

„

SGDV-†††D01A

∗1. Use a 24 VDC power supply with double insulation or reinforced insulation. (The power

supply is not included)

∗2. Before connecting an external regenerative resistor to the SERVOPACK, refer to 3.4 Con-

necting Regenerative Resistors.

∗3. Use a following power supply for 90 V brake. For details, refer to

Σ

-V series Product Cat-

alog (KAEP S800000 42).

• For 200 V input voltage: LPSE-2H01-E
• For 100 V input voltage: LPDE-1H01-E

*1

R S T

100/200 VAC

DC power

supply (24 V)

SGMGV/SGMSV

Servomotor

SGDV-

D01A

SERVOPACK

Power supply
Three-phase 400 VAC

Noise filter

Molded-case

circuit breaker

(MCCB)

Protects the power supply

line by shutting the

circuit OFF when

overcurrent is

detected.

Used to eliminate

external noise from

the power line.

Magnetic

contactor

Turns the servo

ON and OFF.

Install a surge

absorber.

Brake power

supply*

3

Used for a

servomotor

with a 90 V brake.

Turns the brake power

supply

ON and OFF.

Install a surge absorber.

Motor main

circuit cable

Encoder cable

When not using the safety

function, use the SERVOPACK

with the safety function jumper

connector (JZSP-CVH05-E,

provided as an accessory)

inserted.

When using the safety function,

insert a connection cable

specifically for the safety function.

Safety function

devices

I/O signal cable

Connection cable

for digital operator

Connection cable

for personal computer

Digital

operator

Personal

computer

Host controller

Regenerative

resistor*

2

Battery case

(when an absolute

encoder is used.)

Magnetic contactor

Advertising