Get Time Command Block
This functionality allows a remote node to retrieve the clock data from the

ProLinx gateway.

Request Block
The following table describes the structure of the Get Time command block.

Start Word

End Word

Description

0

0

Block ID1 (Command Request Without Response)

1

1

200 or 201 = Get Time (Block ID2)

2

2

Year

3

3

Month

4

4

Day

5

5

Hour

6

6

Minutes

7

7

Seconds & milliseconds

8

98

Reserved for future use

99

99

Block ID1 (Command Request Without Response)


Response Block

Start Word End Word

Description

0

0

200 or 201 = Get Time (Block ID2)

1

1

Block ID1 (Command Request Without Response)

2

2

Year

3

3

Month

4

4

Day

5

5

Hour

6

6

Minutes

7

7

Seconds & milliseconds

8

98

Reserved for future use

99

99

200 or 201 = Get Time (Block ID2)