Hardware and software capacities – Lucent Technologies MERLIN LEGEND 6 User Manual

Page 410

Advertising
background image

MERLIN LEGEND Communications System Release 6.0
System Manager’s Guide

555-660-118

Issue 1

February 1998

System Capacities

Page C-2

C

the equipment (for example, a fax or an answering machine) connected to the
MFM.

Similarly, although the 100D module has only one jack, it can serve up to 24
endpoints (emulated, T1 digital, or PRI facilities). Thus, you can configure the
system to connect up to 80 lines/trunks and 255 extension endpoints, a total of
335 endpoints.

NOTE:

The system has a time-slot capacity of 216. If more than 216 endpoints are
in use at the same time, blocking can occur.

Table C–1

lists the hardware and software capacities of the system. Some

constraining factors appear with a checkmark (



) and are explained at the end of

the table.

If you are planning to expand your system, contact your Lucent Technologies
representative for additional considerations.

Table C–1. Hardware and Software Capacities

Limit

Constraining Factor

Allowed/Disallowed Lists

Number of lists
Entries per list
Digits per entry

8

10

7

Automatic Route Selection

Number of ARS tables
Subpatterns per table
Routes per subpattern
Entries per table
Entries across all tables
Default tables

16

2
6

100

1,600

4

Callback

Number of calls in queue

64

Continued on next page