Outline

Estimates the load inertia of the
machine in real time and sets
up the optimum gain automati-
cally responding to the result.
Also, an adaptive filter can
cope with any load caused by
the resonance.

Applicable Range

Caution

Real-time auto-gain tuning may not be executed properly under the conditions described in the table below.
In these cases, use the normal mode auto-gain tuning (refer to P.148), or execute the manual auto-gain
tuning (refer to P.152).

Real-Time Auto-Gain Tuning Mode

Action command under

actual condition

Position/Velocity

command

Position/Velocity

control

Servo driver

Real time

auto-gain tuning

Resonance frequency

estimation

Load inertia estimation

Adaptive

Filter

current

control

Gain

auto-setup

Filter

auto-adjustment

Torque

command

Motor

current

Motor

speed

Motor

Encoder

Conditions which obstruct real-time auto-gain tuning action

• The load is too small or large compared to the rotor inertia. (less than 3 times or more than 20 times)
• The load inertia changes too quickly (10 [s] or less)

The machine stiffness is extremely low.

A chattering such as backlash exists.

• The motor is running continuously at low speed of (100 [r/min] or lower.

Acceleration/deceleration is slow (2000 [r/min] per 1[s] or low).

Acceleration/deceleration torque is smaller than unbalanced weighted/viscous friction torque.

When the speed condition of 100 [r/min] or more and acceleration/deceleration condition

of 2000 [r/min] per 1 [s] are not maintained for 80 [ms].

Load

Load inertia

Action pattern

Setup value

0

[

1

]

2

3

4

5

6

7

Real time auto-gain tuning

(not in use)

normal mode

vertical axis mode

no gain switching mode

Varying degree of load inertia in motion

no change

slow change

rapid change

no change

slow change

rapid change

no change

When the changing degree of load inertia is large, set up 3 or 6.
When the motor is used for vertical axis, set up 4 to 6.
When vibration occurs during gain switching, set up 7.

Conditions under which the real-time auto-gain tuning is activated

Control mode

Others

• Real time auto-gain tuning is applicable to all control modes.

However, the load inertia estimation will be disabled when a motor trial operation function

is executed and a frequency characteristics measurement function of “PANATERM

®

” is

used.

• The servo turns on.

• Any factors, including Deviation Counter Clear command input inhibition and torque limit,

other than control parameter are set appropriately and the motor can rotate normally

without any problem.

How to Operate

1) Bring the motor to stall (Servo-OFF).
2) Set up SV.Pr21 (Real time auto tuning set up) to 1-7.