Conformity to ec directives and ul standards, Surge absorber – Panasonic MINAS A4P Series User Manual

Page 178

Advertising
background image

178

Surge Absorber

Provide a surge absorber for the primary side of noise filter.

<Remarks>
Take off the surge absorber when you execute a dielectric test to the machine or equipment, or it may
damage the surge absorber.

Conformity to EC Directives and UL Standards

Circuit diagram

Circuit diagram

1

ø

4.2

±

0.2

41

±

1

UL-1015 AWG16

281

5.5

±

1

11

±

1

28.5

±

1

4.5

±

0.5

200

+30 -

0

Option part No.

DV0P1450

3-phase 200V

Manufacturer's part No.

R . A .V-781BXZ-4

Manufacturer

Okaya Electric Ind.

Option part No.

DV0P4190

Single phase 100/200V

Manufacturer's part No.

R . A .V-781BWZ-4

Manufacturer

Okaya Electric Ind.

2

3

ø

4.2

±

0.2

41

±

1

UL-1015 AWG16

281

5.5

±

1

11

±

1

28.5

±

1

4.5

±

0.5

200

+30 -0

1

2

(1)

(2) (3)

(1)

(2)

Voltage specifications

for driver

Voltage specifications

for driver

Option part No.

DV0P3410

3-phase 200V

Applicable driver (frame)

F-frame

Manufacturer's part No.

3SUP-HL50-ER-6B

Manufacturer

Okaya Electric Ind.

Circuit diagram

IN

OUT

286

±

3.0

150

2-ø5.5 x 7

2-ø5.5

6-6M

270

255

±

1.0

240

120

90

±

1.0

(18)

(13)

Label

1

2

3

4

5

6

Voltage specifications

for driver

Advertising