[Adjustment]

Adjustment

Release of Automatic Gain Adjusting Function

SV.Pr2F

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

1st notch frequency [Hz]

(invalid)

(invalid)

(invalid)

(invalid)

(invalid)

1482

1426

1372

1319

1269

1221

1174

1130

1087

1045

1005

967

930

895

861

828

796

SV.Pr2F

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

1st notch frequency [Hz]

766

737

709

682

656

631

607

584

562

540

520

500

481

462

445

428

412

396

381

366

352

339

SV.Pr2F

44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59

60

61

62

63

64

1st notch frequency [Hz]

326

314

302

290

279

269 (invalid when Pr22

>

=

15)

258 (invalid when Pr22

>

=

15)

248 (invalid when Pr22

>

=

15)

239 (invalid when Pr22

>

=

15)

230 (invalid when Pr22

>

=

15)

221 (invalid when Pr22

>

=

14)

213 (invalid when Pr22

>

=

14)

205 (invalid when Pr22

>

=

14)

197 (invalid when Pr22

>

=

14)

189 (invalid when Pr22

>

=

14)

182 (invalid when Pr22

>

=

13)

(invalid)

(invalid)

(invalid)

(invalid)

(invalid)

*Set up 1500 to SV.Pr1D (1st notch frequency) in case of

invalid

of the above table.

Outline

Cautions are described when you want to invalidate the real time auto-gain tuning of default or the adaptive filter.

Caution

Execute the release of the automatic adjusting functions while all action stop (Servo-OFF)

Invalidation of Real-Time Auto-Gain Tuning

You can stop the automatic calculation of SV.Pr20 (Inertial ratio) and invalidate the real-time auto-gain
tuning by setting up SV.Pr21 (Real time auto tuning set up) to 0.
Note that the calculation result of SV.Pr20 (Inertia ratio) will be held, and if this parameter becomes abnor-
mal value, use the normal mode auto-gain tuning or set up proper value manually obtained from formula or
calculation.

Invalidation of Adaptive Filter

When you set up SV.Pr23 (Adaptive filter mode) to 0, adaptive filter function which automatically follows the
load resonance will be invalidated.
If you invalidate the adaptive filter which have been working correctly, noise and vibration may occur due to
the effect of resonance which have been suppressed.
Therefore, execute the copying function of the setup of adaptive filter (SV.Pr2F) to the 1st notch frequency
(SV.Pr1D), or set up SV.Pr1D (1st notch frequency) manually by using the table below, then invalidate this
filter.