Gain switching function, Adjustment – Panasonic MINAS A4P Series User Manual

Page 155

Advertising
background image

155

[Adjustment]

Adjustment

Suppress the vibration by lowering the gain.

Stop

(Servo-Lock)

Low gain

(1st gain)

Low gain

(1st gain)

High gain

(2nd gain)

1ms

2ms

Stop

(Servo-Lock)

Run

Time

Command speed

Action

Status

Gain

Title of parameter

10

11

12

13

14

15

16

18

19

1A

1B

1C

30

31

32

33

34

35

63

35

16

0

65

300

50

0

63

35

16

0

65

1

7

30

0

0

0

27

84

1st position loop gain

1st velocity loop gain

1st velocity loop integration time constant

1st speed detection filter

1st torque filter time constant

Velocity feed forward

Feed forward filter time constant

2nd position loop gain

2nd velocity loop gain

2nd velocity loop integration time constant

2nd speed detection filter

2nd torque filter time constant

2nd gain action set up

1st control switching mode

1st control switching delay time

1st control switching level

1st control switching hysteresis

Position loop gain switching time

20

Inertia ration

Execute manual

gain-tuning

without gain

switching

• Enter the known value
from load calculation
• Measure the inertia
ratio by executing nor
mal auto-gain tuning
• Default is 250

Set up the same

value as SV.Pr10-

14 (1st gain)

to SV.Pr18-1C

(2nd gain)

Set up

SV.Pr30-35

(Gain switching

condition)

Adjust SV.Pr11

and 14 at

stopping

(1st gain)

Servo

Parameter

No.

(SV.Pr**)

Gain Switching Function

At manual gain tuning, you can set 2nd gain
manually in addition to 1st gain and you can
switch the gain depending on the various re-
quirements of the action such cases as,
• you want to increase the response by increas-

ing the gain in motion

• you want to increase the servo-lock stiffness

by increasing the gain at stopping

• switch to the optimum gain according to the

action mode

• lower the gain to suppress the vibration at stopping.

<Example>
Following is the example when you want to reduce the noise at motor in stall (Servo-Lock), by setting up to
lower gain after the motor stops.
• Make adjustment referring to the auto-gain tuning table (P.149) as well.

Advertising