Normal mode auto-gain tuning, How to operate from the console – Panasonic MINAS A4P Series User Manual

Page 150

Advertising
background image

150

Normal Mode Auto-Gain Tuning

(1) Turn to the normal auto-gain tuning
mode from the monitor mode, by
pressing the SET button, then press
the mode switching button three times

.

For details, refer to P.81, "Structure

of Each Mode" of Preparation.

(2)

Enter the machine stiffness No. by pressing .

Display of rotational speed
of the motor (initial display)

Machine stiffness No.

Machine stiffness No. (High)

Machine stiffness No. (Low)

Tuning finishes

normally

Tuning error

Value changes toward the direction as
an arrow shows by pressing and
changes toward the reversed direction
by pressing .

(3) Shift to MONITOR/EXECUTION mode
by pressing .

(4)

Operation at MONITOR/EXECUTION mode

Keep pressing until the display

changes to .

• Pin-29 of the connector, CN X5 to be

Servo-ON status.

Keep pressing for approx.3sec,

then bar increase as the right fig. shows.

The motor starts rotating.

For approx. 15 sec, the motor repeats

max. 5 cycles of CCW/CW rotation,

2 revolutions each direction per one cycle.

Tuning may finish before 5th cycles,

however, this is not an error.

(5) Write the gain value to EEPROM to prevent

them from being lost due to the power shut off.

Drive method

Ball screw direct connection

Ball screw + timing belt

Timing belt

Gear, Rack & Pinion

Others, low stiffness machine

Machine stiffness No.

8 to 14

6 to 12

4 to 10

2 to 8

0 to 8

Content

Display of error.

Value of parameter

related to gain (such as

SV/Pr10) is kept as same

as before the execution.

Cause

One of alarm, Servo-OFF or

deviation counter clear has

occurred.

Load inertia cannot be identi-

fied.

Measure

• Avoid an operation near the limit switch or home sensor switch.

• Turn to Servo-ON.

• Release the deviation counter clear

• Lower SV.Pr10 to 10 and SV.Pr11 to 50, then execute the

tuning.

• Adjust the gain manually. (Calculate the load inertia, and then

enter.)

How to Operate from the Console

<Caution>
Do not use the normal mode auto-gain tuning with the motor and driver alone. SV.Pr20 (Inertia ratio)
becomes to 0.

<Notes>

Advertising