Damping control, Adjustment, Outline – Panasonic MINAS A4P Series User Manual

Page 161: Applicable range, Caution, How to use, Damping filter setup

Advertising
background image

161

[Adjustment]

Adjustment

Damping Control

Outline

This function reduces the vibration by removing
the vibration frequency component from the com-
mand when the load end of the machine vibrates.

Applicable Range

This function can only be applicable when the following conditions are satisfied.

Caution

When you change the parameter setup or switch with VS-SEL, stop the action first then execute.

This function does not work properly or no effect is obtained under the following conditions.

How to Use

(1) Setup of damping frequency (1st : SV.Pr2B, 2nd : SV.Pr2D)

Measure the vibration frequency of the front edge of the machine.
When you use such instrument as laser displacement meter, and can
directly measure the load end vibration, read out the vibration fre-
quency from the measured waveform and enter it to SV.Pr2B or
SV.Pr2D (2nd vibration suppression frequency).

(2) Setup of damping filter (1st : SV.Pr2C, 2nd : SV.Pr2E)

First, set up 0.
You can reduce the settling time by setting up larger
value, however, the torque ripple increases at the
command changing point as the right fig. shows.
Setup within the range where no torque saturation
occurs under the actual condition. If torque satura-
tion occurs, damping control effect will be lost.

<Remark>
Limit the damping filter setup with the following formula.
10.0 [Hz] – Damping frequency

<

=

Damping filter setup

<

=

Damping frequency

(3) Setup of damping filter switching selection

(SV.Pr24)

You can switch the 1st or the 2nd damping filter depending on the vibration condition of the machine.

Control mode

Conditions under which the damping control is activated

• Control mode to be either or both position control or/and full-closed control.

SV.Pr02 = 0 : Position control

SV.Pr02 = 6 : Full-closed control

Command
speed

Position deviation

Calculation of
vibration frequency

Torque
command

Torque saturation

Damping filter setup is
too large.

Damping filter setup is
appropriate.

Switching mode

No switching ( Both of 2 are valid.)

Switch with command direction.

CCW : 1st damping filter

CW : 2nd damping filter

SV.Pr24

0, 1

2

Servo driver

Motor position

Motor

Coupling

Ball

screw

Work

travel

Driver

PLC

Setup of front edge vibration
frequency

Motor

Encoder

Load

Position

command

Damping

filter

Position/Velocity

control

Torque

command

Current

control

Machine

base

Front edge vibrates.

Vibration
measurement
with
displacement
sensor

Motor

current

Load

Conditions which obstruct the damping control effect

• Vibration is triggered by other factors than command (such as disturbance).

• Ratio of resonance frequency and anti-resonance frequency is large.

• Vibration frequency is out of the range of 10.0 to 200.0 [Hz].

Advertising