83

[Setting]

Setting

Display of Position Deviation, Motor Rotational Speed and Torque Output

Display of Control Mode

..........Positional deviation (cumulative pulse counts of deviation counter)
• – display : generates rotational torque of CW direction (viewed from shaft end)
no display : generates rotational torque of CCW direction (viewed from shaft end)

..........Rotational speed of the motor unit [r/min]
• – display : CW rotation, no display : CCW rotation

..........Torque command unit [%] (100 for rated torque)
• – display : CW rotation, no display : CCW rotation

Data

<Note>

+

is not displayed on LED, but only

-

appears.

.....Position control mode

.....Full-closed control mode

Display of I/O Signal Status

Displays the control input and output signal to be connected to CN X5 connector.

.....Input signal

.....Output signal

(Lowest place
No. of input
signal)

(Highest place
No. of input
signal)
(Lowest place
No. of output
signal)

(Highest place
No. of output
signal)

Signal No.
(Hexadecimal number, 0 to 1F)

.....Active
(This signal is valid)
.....Inactive
(This signal is invalid)

Select the signal No. to be monitored by pressing .

Transition when
pressing .

<Note>

• Shift the flashing decimal point with .

• The other way to change signal No. at I/O
selection mode Signal selection mode.

(Right side of decimal point :
Signal selection mode)

(Left side of decimal point :
Input/Output selection mode)

Advertising