[Setting]

Setting

58

0 to 1

<1>

Point specifying

input logic setting

Set the logic of the point specifying inputs (P1IN to P32IN: CN X5 Pin 3, 4, 5, 6, 7 and 8).

Setup value

0

<1>

Description

Point

specifying

inputs are enabled by opening the connection to COM

.

Point

specifying

inputs are enabled by closing the connection to COM

.

59

0 to 1

<1>

Multi-function

input 1 Signal logic

Set the logic of the multi function input 1 (EX-IN1: CN X5 Pin 22).

Setup value

0

<1>

Description

Input is enabled by opening the connection to COM

.

Input is enabled by closing the connection to COM

.

5A

*

0 to 6

<0>

Multi-function

input 1 Signal

selection

Set the function of the multi function input 1 (EX-IN2: CN X5 Pin 22).

Setup value

<0>

1

2

3

4

5

6

Description

Disabled (regardless of the logic setting in SV.Pr59).

Immediate stop

Temporary stop

Deceleration and stop

High-speed normal rotation jog

High-speed reverse rotation jog

Alarm is cleared.

5B

0 to 1

<1>

Multi-function

input 2 Signal logic

Set the logic of the multi function input 2 (EX-IN2: CN X5 Pin 25).

Setup value

0

<1>

Description

Input is enabled by opening the connection to COM

.

Input is enabled by closing the connection to COM

.

5D

0 to 1

<1>

Servo-ON input

valid

Specify whether to enable or disable the servo-on input (SRV-ON: CN X5 Pin 23).

5C

*

0 to 6

<0>

Multi-function

input 2 Signal

selection

Set the function of the multi function input 2 (EX-IN2: CN X5 Pin 25).

<Note>

The setting of the multi function input 1 and that of the multi function input 2 must be
different from each other. Moreover, if high-speed normal rotation jog and high-
speed reverse rotation jog are assigned to the input 1 and input 2, respectively, the
motor does not work when those turn on simultaneously.

Setup value

<0>

1

2

3

4

5

6

Description

Disabled (regardless of the logic setting in SV.Pr5B).

Immediate stop

Temporary stop

Deceleration and stop

High-speed normal rotation jog

High-speed reverse rotation jog

Alarm is cleared.

Setup value

0

<1>

Description

Disable:

A servo turns on after the power supply turns on, regardless of the state

of servo-on input (SRV-ON: CN X5 Pin 23).

Enable:

A servo turns on when the servo-on input (SRV-ON: CN X5 Pin 23) has

been input after the power supply turns on.

Servo

PrNo.

Setup

range

Title

Function/Content

Standard default : < >