Preparation, Others – Panasonic MINAS A4P Series User Manual

Page 47

Advertising
background image

47

[Preparation]

Preparation

<Note>

• When the output source is the encoder

• If the encoder resolution X is multiple of 4, Z-phase will be fed out synchronizing with A-phase.

In other case, the Z-phase width will be equal to the encoder resolution, and will not synchronize with
A-phase because of narrower width than that of A-phase.

• In case of the 5-wire, 2500P/r incremental encoder, the signal sequence might not follow the above fig.
until the first Z-phase is fed out. When you use the pulse output as the control signal, rotate the motor
one revolution or more to make sure that the Z-phase is fed out at least once before using.

SV.Pr44
SV.Pr45

A

B

Z

A

B

Z

synchronized

not-synchronized

SV.Pr44
SV.Pr45

when the encoder resolution is multiple of 4,

SV.Pr44
SV.Pr45

when the encoder resolution is not multiple of 4,

Frame ground

Signal ground

FG

GND

18

26

• Internally connected to the ground terminal inside the servo driver.

• Signal ground
• Internally insulated from the control signal power supply (COM–) inside the

servo driver.

Application

Code

Function

Connector

pin No.

Others