List of signal for connector cn x5, System configuration and wiring, Common input signals – Panasonic MINAS A4P Series User Manual

Page 44

Advertising
background image

44

System Configuration and Wiring

List of Signal for Connector CN X5

Common input signals

Application

Code

Function

Connector

pin No.

Control signal
power supply

COM+

COM–

1

17

• Connected to the + terminal of an external DC power supply (12 to 24 V)
• Use a 12 V (

±

5%) to 24 V (

±

5%) power supply.

• Connected to the – terminal of an external DC power supply (12 to 24 V).
• The power supply capacity differs depending on the configuration of the

input/output circuits used. A capacity of more than 0.5A is recommended.

Emergency
stop input

EMG-
STP

2

• When connection with COM– is opened, emergency stop input error (error

code No.39) occurs, and the circuit trips.

• Tripping can be reset using an alarm clear input initiated by specifying point

0 or assigning the multi-function inputs (EX-IN1, EX-IN2).

Point specifying
input

• Specify an operation point number when operation command is input.
• The number at which operation point can be specified depends on the

number of points set by SV.Pr57.

• SV.Pr58 can be used for setting input logic.
When the point described below is specified, special operation is

performed.

1)Specify point 0, and input a strobe signal, then alarm is cleared.
2)Specify the maximum point number specified in SV.Pr57, and input a

strobe signal, then system returns to the home position.

3)Specify the maximum point number specified in SV.Pr57 –1 and input a

strobe signal, then high-speed normal rotation jog is performed.

4)Specify the maximum point number specified in SV.Pr57 –2 and input a

strobe signal, then high-speed reverse rotation jog is performed.

CCW over-
travel
inhibit input

CCWL

19

• CCW drive prohibition input (CCWL).
• Connect so as to open COM– connection when movable part of the

equipment exceeds the movable range in CCW direction.

• When this input is open, operation command in CCW direction is not

issued. (Torque is generated)

• SV.Pr53, 54, and 55 enable for setting of valid/invalid, input logic, and

operation.

P1IN

P2IN

P4IN

P8IN

P16IN

P32IN

3

4

5

6

7

8

CW over-travel
inhibit input

CWL

20

• CW drive prohibition input (CWL).
• Connect so as to open COM– connection when movable part of the

equipment exceeds the movable range in CW direction.

• When this input is open, operation command in CW direction is not issued.

(Torque is generated)

• SV.Pr53, 54, and 55 enable setting of valid/invalid, input logic, and

operation.

Home sensor
input

Z-LS

21

• Connect so as to close the home sensor input when system is in the

vicinity of home position (default).

SV.Pr56 can be used for setting input logic.
• Connected to the home sensor signal.

Servo-ON sig-
nal input

SRV-ON

23

• Connect so as to close the home sensor input when system is in the

vicinity of home position.

Pr56 can be used for setting input logic.
• When servo driver is connected to COM– of control signal power supply, it is

set in servo-ON condition.

• When connection to COM– is opened, servo-OFF condition is set, and

energization of motor is cut off.

• Dynamic brake operation and deviation counter clearing operation in servo-OFF

condition can be chosen by SV.Pr69 (sequence at servo-off).

• SV.Pr5D enable setting of valid/invalid.
<Notes>
1)When shifting from servo-OFF to servo-ON, make sure that the motor is

stopped.

2)After shifting to servo-ON, allow 100ms or more before giving an

instruction.

3)Frequent repeating of servo-ON/OFF may damage the dynamic brake

circuit contained in servo driver. Avoid such a use.