How to Use the Console

32-Bit Positioning Parameter

32-bit positioning parameter can be set.

.....32.Pr01

.....32.Pr00

Selected 32.PrNo.

* The data is shown on the
two screens because of
a large number of displayed
digits.

.....32.Pr05

<Notice>
Select an input digit (a dot blinks) by the [SHIFT] key and a parameter by the [UP]/[DOWN] key.
The 32-bit positioning parameter is shown on the two screens because of a large number of displayed
digits.
If the parameter is a negative value, a dot lights.
When you press the [SET] key, the parameter is modified.

* When you press during parameter setting, any parameter in process is not changed and “No.”

display is shown again.

* When you have set the parameters, write the parameters into EEPROM. If you turn the power supply

off before writing the parameters into EEPROM, those parameters are cleared.