background image

Chapter 14 xDSL Profiles Setup

IES-708-22A User’s Guide

125

Figure 55 Basic Setting > xDSL Profiles Setup > Alarm Profile

The following table describes the labels in this screen.

Table 26 Basic Setting > xDSL Profiles Setup > Alarm Profile

LABEL

DESCRIPTION

Port Profile

Click Port Profile to open the Port Profile screen (see

Section 14.3 on page

118

). Use the Port Profile screen to configure profiles of DSL port settings

(such as the transfer rate, interleave delay and signal to noise ratio settings).

VC Profile

Click VC Profile to open the VC Profile screen where you can configure virtual

channel profiles (see

Section 14.7 on page 123

).

IGMP Filter Profile

Click IGMP Filter Profile to open the IGMP Filter Profile screen where you can

configure IGMP multicast filter profiles (see

Section 14.10 on page 127

).

Name

This field is read-only if you click Modify to edit a port profile. Type a name to

identify the alarm profile (you cannot change the name of the DEFVAL profile).

You can use up to 31 English keyboard characters; spaces are not allowed.

Add

Click Add to save your changes to the IES-708-22A’s volatile memory. The IES-

708-22A loses these changes if it is turned off or loses power, so use the Config

Save link on the navigation panel to save your changes to the non-volatile

memory when you are done configuring.

Cancel Click

Cancel to start configuring the screen again.

Threshold

Specify limits for the individual performance counters. The IES-708-22A sends

an alarm trap and generates a syslog entry when one of these thresholds is

exceeded. A value of 0 disables the alarm threshold.

Loop Attenuation

The permitted attenuation (reduction of signal amplitude) of a port’s connection.

SNR Margin

The permitted signal to noise ratio margin.

ES

The number of Errored Seconds (0~900) that are permitted to occur within 15

minutes.

SES

The number of Severely Errored Seconds (0~900) that are permitted to occur

within 15 minutes.

CRCanomalies

The number of Cyclic Redundancy Checking anomalies that are permitted to

occur within 15 minutes.

LOWS

The number of Loss Of Sync Word Seconds (0~900) that are permitted to occur

within 15 minutes.