The following table describes the labels in this screen.

Table 11 Basic Setting > System Information

LABEL

DESCRIPTION

System Name

This field displays the device's model name, including STU-R/STU-C mode.

ZyNOS F/W Version This field displays the version number of the device’s current firmware including

the date created.

DSL Driver Version

This field displays the Digital Subscriber Line firmware version number.

DSP Code Version

This field displays the Digital Signal Processor firmware version number. This is

the modem code firmware.

Hardware Version

This is the version of the physical device hardware. This field may be blank.

Serial Number

This is the individual identification number assigned to the device at the factory.

This field may be blank.

Ethernet Address

This field refers to the Ethernet MAC (Media Access Control) address of the

device.

Hardware Monitor

Enable

Select this check box to turn the hardware monitor on or clear it to turn the

hardware monitor off.

Temperature Unit

Select C to display all temperature measurements in degrees Celsius. Select F

to display all temperature measurements in degrees Fahrenheit.

Temperature Each

temperature sensor can detect and report the temperature. Temperature

sensor 1 is near the DSL chipset. Temperature sensor 2 is near the central

processing unit. Temperature sensor 3 is at the hardware monitor chip.

Current

This shows the current temperature at this sensor.

MAX

This field displays the maximum temperature measured at this sensor.

MIN

This field displays the minimum temperature measured at this sensor.

Average

This field displays the average temperature measured at this sensor.

Threshold (Low)

This field displays the lowest temperature limit at this sensor.

Threshold (Hi)

This field displays the highest temperature limit at this sensor.

Status

This field displays Normal for temperatures below the threshold and Over for

those above.

Voltage(V)

The power supply for each voltage has a sensor that can detect and report the

voltage.

Current

This is the current voltage reading.

MAX

This field displays the maximum voltage measured at this point.

MIN

This field displays the minimum voltage measured at this point.

Average

This field displays the average voltage measured at this sensor.

Threshold (Low)

This field displays the lowest voltage limit at this sensor.

Threshold (Hi)

This field displays the highest voltage limit at this sensor.

Status

Normal indicates that the voltage is within an acceptable operating range at this

point; otherwise Abnormal is displayed.

Use this section of the screen to configure the hardware monitor threshold

settings.

New threshold
Apply

Configure new threshold settings in the fields below and click Apply to use

them.

Index

This field is a sequential value.

Advertising