7 log format, Table 91 log format – ZyXEL Communications IES-708-22A User Manual

Page 272

Advertising
background image

Chapter 44 Alarm Commands

IES-708-22A User’s Guide

272

This command lists alarm settings.
The following example displays the supported minor level alarms for all alarm categories,
facilities, types of alarm messages and conditions.

44.7 Log Format

The following table describes the columns in the list.

<target>

=

snmp|syslog|all

The type of alarm messages that the device

is to send (SNMP, syslog or all).

<condition>

=

Text description for the condition.

ras> alarm tablelist
no alarm condition facility snmp syslog severity clearable
--- ----- ------------------------- -------- ---- ------ -------- -------
1 dsl ( 5000)line_up local1 V V info -
2 dsl ( 5001)line_down local1 V V minor V
3 dsl ( 5002)shdsl_tca_atten local1 V V info V
4 dsl ( 5003)shdsl_tca_snrm local1 V V info V
5 dsl ( 5004)shdsl_tca_es local1 V V info V
6 dsl ( 5005)shdsl_tca_ses local1 V V info V
7 dsl ( 5006)shdsl_tca_crc local1 V V info V
8 dsl ( 5007)shdsl_tca_losw local1 V V info V
9 dsl ( 5008)shdsl_tca_uas local1 V V info V
10 eqpt (10000)vol_err local1 V V critical -
11 eqpt (10001)temp_err local1 V V critical -
12 eqpt (10002)hw_rtc_fail local1 V V critical -
13 eqpt (10003)hw_mon_fail local1 V V critical -
14 eqpt (10004)cold_start local1 V V info -
15 eqpt (10005)warm_start local1 V V info -
16 sys (15000)reboot local1 V V info -
17 sys (15001)aco local1 V V info -
18 sys (15002)alm_clear local1 V V info -
19 sys (15003)login_fail local1 V V minor V

Press any key to continue, 'e' to exit, 'n' for nopause

Table 91 Log Format

LABEL

DESCRIPTION

no

This is the index number of the alarm entry in this list display.

alarm

This is the category of alarms. eqpt represents equipment alarms. dsl

represents Digital Subscriber Line (DSL) alarms. enet represents Ethernet

alarms. sys represents system alarms.

condition

There is a condition code number for the specific alarm message and a text

description for the condition under which the alarm applies.

facility

This is the log facility (local1~local7) on the syslog server where the system is to

log this alarm. This is for alarms that send alarms to a syslog server.

snmp

This displays “V” if the system is to send this alarm to an SNMP server. It

displays “-“ if the system does not send this alarm to an SNMP server.

Advertising