3 tls pvc show command – ZyXEL Communications IES-708-22A User Manual
Page 367
Chapter 54 Virtual Channel Management
IES-708-22A User’s Guide
367
This command sets the second VLAN tag to add to the packets from the PVC.
The following example adds VLAN tag
100
to traffic using the
DEFVAL
ATM profile on PVC
(
1/33
) on port
2
.
54.7.3 TLS PVC Show Command
Syntax:
ras> shdsl tlspvc show [<portlist> [<vpi> <vci>]]
where
This command displays the TLS settings for the specified port(s) or PVC(s). The following
example shows the TLS settings on port 2.
<DS vcprofile
=
Assign a VC profile to use for this channel’s downstream traffic
shaping.
[,US
vcprofile]>
=
Assign a VC profile to use for policing this channel’s upstream
traffic. The IES-708-22A does not perform upstream traffic
policing if you do not specify an upstream VC profile.
<pvid>
=
1 – 4094; the (second) VLAN Identifier to add to Ethernet
frames that the system routes using this PVC.
<priority>
=
Set the IEEE 802.1p priority (0~7) to add to the traffic that uses
this PVC.
ras> shdsl tlspvc set 2 1 33 DEFVAL 100 0
<portlist>
=
The port number of the TLS PVC. You can specify a single DSL
port <1>, all DSL ports <*> or a list of DSL ports <1,3,5>. You
can also include a range of ports <1,5,6~8>.
<vpi>
=
The VPI of the TLS PVC.
<vci>
=
The VCI of the TLS PVC.
ras> shdsl tlspvc show 2
port vpi vci pvid pri DS/US vcprofile
---- --- ----- ----- --- ----------------------------------
2 1 33 100 0 DEFVAL