Chapter 44 Alarm Commands

IES-708-22A User’s Guide

270

This command displays the current alarms by severity, alarm category, alarm condition, or
date.
The following example displays the current critical level alarms for all alarm categories and
conditions.
The source is where the alarm originated. This is either a DSL port number, one of the
Ethernet ports (enet 1 or 2), or “eqpt” for the system itself.

44.4 Alarm Port Show Command

Syntax:

ras> alarm port show [<severity>|all]

where

This command displays port alarm severity level thresholds. The system reports an alarm on a
port if the alarm has a severity equal to or higher than the port’s threshold.

<sdate>

=

Start date (yyyy/mm/dd)

<edate>

=

End date (yyyy/mm/dd)

[for|rev]

=

Display order. for: forward; rev: reverse.

[detail]

=

Display in-depth alarm information.

ras> alarm show

[current alarm list]
no alarm condition severity timestamp source
------ ------ -------------------- -------- -------------- -------
1 eqpt +vol_err critical 01/01 00:00:07 eqpt 3
2 dsl +line_down minor 01/01 02:16:27 6
3 dsl +line_down minor 01/01 02:16:27 5
4 dsl +line_down minor 01/01 02:16:28 4
5 dsl +line_down minor 01/01 02:16:28 3
6 dsl +line_down minor 01/01 02:16:29 2
7 dsl +line_down minor 01/01 02:16:29 1

<severity>

=

Alarm severity. info|minor|major|critical