Chapter 36 Static Routing

IES-708-22A User’s Guide

228

Metric

The metric represents the “cost” of transmission for routing purposes. IP routing

uses hop count as the measurement of cost, with a minimum of 1 for directly

connected networks. Enter a number that approximates the cost for this link.

The number need not be precise, but it must be between 1 and 15. In practice, 2

or 3 is usually a good number.

Add

Click Add to save the new rule to the IES-708-22A’s volatile memory. It then

displays in the summary table at the bottom of the screen. The IES-708-22A

loses these changes if it is turned off or loses power, so use the Config Save

link on the navigation panel to save your changes to the non-volatile memory

when you are done configuring.

Cancel

Click Cancel to reset the fields to your previous configuration.

Use this section to look at a summary of all static routes in the IES-708-22A.

Previous Page

Click this to display the preceding page of static route entries.

Next Page

Click this to display the following page of static route entries.

Index

This field displays the index number of the route.

Name

This field displays the name of this static route.

Destination Address This field displays the IP network address of the final destination.

Subnet Mask

This field displays the subnet mask for this destination.

Gateway Address

This field displays the IP address of the gateway. The gateway is an immediate

neighbor of your device that will forward the packet to the destination.

Metric

This field displays the cost of transmission for routing purposes.

Delete

Select the rule(s) that you want to remove in the Delete column, and then click

the Delete button.

Cancel

Click Cancel to clear the selected check boxes in the Delete column.

Table 80 Routing Protocol > Static Routing (continued)

LABEL

DESCRIPTION

Advertising