Chapter 44 Alarm Commands
IES-708-22A User’s Guide
271
The following example displays the port alarm thresholds for all ports. “ifindex” identifies the
interface.
44.5 Alarm Port Set Command
Syntax:
ras> alarm port set <all|<portlist>> <severity>
where
This command sets the alarm severity threshold for recording alarms on an individual port(s).
The system reports an alarm on a port if the alarm has a severity equal to or higher than the
port’s threshold.
The following example has the IES-708-22A only record critical alarms on DSL port 7.
44.6 Alarm Tablelist Command
Syntax:
ras> alarm tablelist [<alarm>|all] [<severity>|all] [<fac>|all]
[<target>[,<target>]] [<condition>|all]
where
ras> alarm port show
no ifindex severity
------ ------- --------
01 01 minor
02 02 minor
03 03 minor
04 04 minor
05 05 minor
==================================== SNIP =================================
<all|portlist>
=
Ports on the IES-708-22A.
<severity>
=
Alarm severity. info|minor|major|critical
ras> alarm port set 7 critical
<alarm>
=
Alarm category. sys|eqpt|enet|dsl|voip
<severity>
=
Alarm severity. info|minor|major|critical
<fac>
=
The log facility (
local1~local7
) that has the device log the
syslog messages to different files in the syslog server. See your
syslog program’s documentation for details.