Multi-Service IronWare Routing Configuration Guide

299

53-1003033-02

Displaying IPv4 IS-IS information

Circuit Type

The type of IS-IS circuit running on the interface. The circuit type can be
one of the following:

BCAST (broadcast).

PTP (Point-to-Point)

Passive State

The passive state determines whether the interface is allowed to form an
IS-IS adjacency with the IS at the other end of the circuit. The state can
be one of the following:

FALSE – The passive option is disabled. The interface can form an
adjacency with the IS at the other end of the link.

TRUE – The passive option is enabled. The interface cannot form
an adjacency, but can still advertise itself into the area.

Circuit Number

The ID that the instance of IS-IS running on the interface applied to the
circuit between this interface and the interface at the other end of the
link.

MTU

The maximum length supported for IS-IS PDUs sent on this interface.

Level-1 Auth-mode

One of the following authentication modes set for Level-1 on the router:

None

md5

cleartext

Level-2 Auth-mode

One of the following authentication modes set for Level-2 on the router:

None

md5

cleartext

This parameter is not displayed for interfaces that are configured with a
Point-to-Point circuit type. This is because separate Level-2 Hello
messages are not sent on Point-to-Point interfaces. Consequently, "Hello
Interval", "Hello Multiplier", and "Authentication" parameters should
always be configured in the Level-1 mode for Point-to-Point interfaces.

Level-1 Metric

The default-metric value that the Brocade device inserts in IS-IS Level-1
PDUs for this interface.

Level-1 Priority

The priority of this IS to be elected as the Designated IS for Level-1 in this
broadcast network.

Level-1 Hello Interval

The number of seconds the software waits between sending Level-1
hello PDUs to the IS at the other end of the circuit.

Level-1 Hello Multiplier

The number by which the software multiplies the hello interval to
calculate the hold time set in Level-1 Hello PDUs sent on the circuit.

Level-1 Designated IS

The NET of the Level-1 Designated IS.

Level-1 DIS Changes

The number of times the NET of the Level-1 Designated IS has changed.

Level-2 Metric

The default-metric value that the Brocade device inserts in IS-IS Level-2
PDUs for this interface.

Level-2 Priority

The priority of this IS to be elected as the Designated IS for Level-2 in this
broadcast network.

Level-2 Hello Interval

The number of seconds the software waits between sending Level-2
Hello messages to the IS at the other end of the circuit.

TABLE 42

IS-IS interface information (Continued)

This field...

Displays...