ADC Release 3.1 User Manual

Page 157

Advertising
background image

1152700

Issue 1

February 2001

Section 2 Operation and Maintenance

Page 2-137

2000, ADC Telecommunications, Inc.

DLP-723

Page 5 of 5

Table 723-1. Subnetwork Connection Configuration Options

SELECTION

OPTIONS

DESCRIPTION

Connection Name

User Defined

Displays the connection name selected for
configuration. User may rename the connection
by typing in a new name and hitting Apply.

Segment Endpoint

Single selection box

Sets this end of the connection as a segment
endpoint for OAM cells.

Ingress / Egress NDC

On or Off

Enables or disables the network data collection for
selected circuit.

Test Type

End to End OAM

Segment OAM

Continuity Check Source

Continuity Check Sync

No Test

No test is currently being administered.

Loopback Location ID

Customer assigned location identifier, used to
loopback the incoming signal and transmit it back
to the customer equipment, limited to 16 numeric
characters.

Insert Loopback Cells

Towards Access Facility

Towards Ring Facility

Test Status

None

Active

Test is not currently active.

Test is currently in progress.