Table 762-1. Display T3 TMUX Multi 1 and TMUX EXP Card Status Definitions, continued

ITEM

STATUS

DEFINITION

ACTION

Transmit Line
State

Xmt RAI
Alarm

Xmt AIS

Card transmitting a Remote
Alarm Indication signal (RAI)
to customer equipment.

Card is transmitting an AIS
signal.

Check VP connection per DLP-709,
and remote transmit end.

Check local T3 signal input.

Receive Line
State

No Alarm

Rcv AIS

Rcv RAI
Failure

Rcv Test Code

T3 line is operating within
normal parameters.

Card is receiving an Alarm
Indication Signal (AIS).

Access interface (AIC)
Receiving Remote Alarm
Indication.

Card is receiving a test signal
input.

No action required.

Check remote end T3 input signal.

Check VP connection per DLP-709,
and local access interface.

Check with administrator for testing
activity.

Other

LOF

LOS

Loopback
State

Input signal frame format not
recognized.

No input signal being
received.

Card has been manually set to
loop signal back to customer
equipment.

Verify correct frame format setting
and change if needed per DLP-754.

Check metallic input and DSX.

Check customer end for
troubleshooting activity. If required,
release loopback per DLP-772.