ADC Release 3.1 User Manual

Page 297

Advertising
background image

1152700

Issue 1

February 2001

Section 2 Operations and Maintenance

Page 2-277

© 2000, ADC Telecommunications, Inc.

DLP-762

Page 3 of 6

Table 762-1. Display T3 TMUX Multi 1 and TMUX EXP Card Status Definitions, continued

ITEM

STATUS

DEFINITION

ACTION

Availability
Status

Available

In Test

Failed

Power Off

Not Installed

Off Line

Dependency

Unknown

Card is ready for processing
commands.

Card is currently processing test
signals.

Card has failed operation and
system has placed it out of
service.

No power to the card.

Card is not currently installed in
selected slot of the shelf.

Card is installed and
provisioned but currently off
line.

Card is supplying timing
reference, traffic, or other data
to the system.

The system processor does not
currently know the availability
status.

No action required.

Wait a few seconds for screen to
update.

Card may be performing a reset, or
the bus may be busy.

Check power source, replace card if
source is good per DLP-777.

If required, install card in selected
slot per DLP-777 and provision per
DLP-754.

If required, set module on line per
DLP-754.

Perform a soft switch over (manual)
per DLP-771 to release card
dependency if removing.

Wait for processor to update current
status, may need to perform a manual
reset of SC per DLP-773.

Protection
State

Not Protected

Enabled

Manual switch

Forced Switch

Lockout

Unknown

Not Protected

Protection is available for
selected card but is not active.

User has manually switched the
card to protection.

User has forced card to
protection.

Card cannot switch to
protection. It has been locked
out by command or switch
count.

Protection status information is
not available to the shelf
controller.

If equipped, set up a protection group
and provision card for protection per
DLP-753.

No action necessary.

If required, switch the card back per
DLP-771.

If required, release forced switch per
DLP-771.

If required, release manual lock-out
per DLP-771.

Wait a few minutes and update
screen. May need to reset SC, refer to
DLP-773.

(continued)